Latest regulations of the Ministry of Construction on apartment elevators

The Ministry of Construction has issued Circular 03/2021/TT-BXD stipulating national standards on apartment buildings, including some additional requirements for elevators in apartment buildings. Circular takes effect from July 5, 2021.

Having many serious accidents related to elevators in apartment buildings, Ministry of Construction has issued Circular 03/2021/TT-BXD stipulating national standards on apartment buildings. There are additional requirements for elevators in apartment buildings.

Minimum number of elevators in the apartment

Apartment buildings, mixed-use apartment buildings of 5 floors or more must have at least 1 elevator; Building from 10 floors or more, there must be at least 2 elevators.

In an apartment building or a mixed-use apartment building with an elevator, there must be at least 1 dedicated elevator with internal dimensions of the cabin enough for emergency bed.

It is necessary to arrange at least 1 elevator for 200 people residing in the building or at least 1 elevator for 70 apartments. Lift capacity must be not less than 450 kg (previously 400 kg). In case the house has an elevator, the minimum capacity of the elevator is not less than 630 kg.

Requirements on fire protection

For apartment buildings, mixed-use apartment buildings with a height of more than 50 m or with a depth of the basement floor (considering the height of the exit to the outside) greater than 9 m, each fire compartment of the building must have at least one elevator meeting the requirements of transporting forces, means of firefighting and rescue according to TCVN 6396-72:2010 and TCVN 6396-73:2010.

Safety requirements

The width of the passenger elevator lobby must be arranged in accordance with the applicable standards.

Lifts must have anti-jamming protection devices, automatic rescue system and internal telephone systems from the cabin to the outside. Elevators can only operate when all doors are closed.

Inspection requirements

Elevators must ensure safety according to QCVN 02:2019/BLDTBXH and be tested for safety before being put into use in the following cases:

– After installation

– After carrying out major repairs

– After a serious accident and it was fixed

– Expiry of inspection or at the request of the state management agency in charge of occupational safety.

Requirement for machine room

The machine room of the apartment elevator must meet the following requirements:

– There is a safe way to and from the machine room, convenient for maintenance, repair and rescue work

– Machine room is not located directly on the apartment

– The elevator shaft must meet the requirements of sound insulation according to QCXDVN 05:2008/BXD and noise protection according to QCVN 26:2010/BTNMT.

– Do not arrange a water tank directly on the elevator shaft and do not allow the water supply, heating and gas supply pipes to go through the elevator shaft.

Elevator requirements must be ensured for the elderly and disabled

Access to use according to QCVN 10:2014/BXD.

- Minimum door width 900mm

– Minimum cabin size 1100mm x 1400mm

– The size of the waiting space in front of the elevator door is not less than 1400mm x 1400mm

– The control panel is not placed higher than 1200mm and not lower than 900mm from the cabin floor to the highest button.

– On the control buttons must have characters with contrasting colors or Braille system.


Other news

Vietnam Elevator Expo 2023 officially gets underway

Vietnam Elevator Expo 2023 officially gets underway

On the morning of December 7th, 2023, two events were inaugurated simultaneously at the Saigon Exhibition and Convention Center (SECC) in Ho Chi Minh City, Vietnam. These events are the Vietnam International Trade Fair (Vietnam Expo) and the International Elevator Exhibition – Vietnam Elevator Expo 2023.
The elevator industry from a sustainability perspective

The elevator industry from a sustainability perspective

On December 7th, during the Vietnam Elevator Expo 2023, an International Seminar was held titled “Sustainable Development Trend of Future Elevator Industry” organized by the Vietnam Elevator Association (VNEA).
Series of outstanding events at Vietnam Elevator Expo 2023

Series of outstanding events at Vietnam Elevator Expo 2023

Vietnam Elevator Expo 2023 will be hosting a variety of exciting events in addition to showcasing and introducing products. Some of the noteworthy sideline activities include the International Elevator Seminar, International Cooperation Signing Ceremony, Awards Ceremony,…
Vietnam is attending International Lift Expo Korea for the first time

Vietnam is attending International Lift Expo Korea for the first time

EM – ILEK 2023 is the foremost elevator exhibition in Korea and offers an excellent chance for elevator, escalator, and auxiliary businesses to network and collaborate. The Vietnam Elevator Association, as a representative of the Vietnamese elevator industry, will also be participating in this exhibition in its 2023 edition.
Announcement of the CIP of Vietnam Elevator Expo

Announcement of the CIP of Vietnam Elevator Expo

“Connect, create, develop” – those are the keywords of the Vietnam Elevator Expo - The international exhibition of elevators, escalators - technology & accessories. This is also evident in the new brand identity of this event announced by the Vietnam Elevator Association.
5 important Vietnamese standards about elevators

5 important Vietnamese standards about elevators

Elevators are regulated in the list of "machines, equipment, materials and substances subject to strict requirements on occupational safety and hygiene". Therefore, the Vietnam Standards (TCVN) were regulated to standardize the process of manufacturing, testing, operating and using elevators.

Enterprise introduction

General events